     www.honeywell.com/sensing sensing and control interactive catalog...  

   
  
 
 
 

manual switches at series toggle switch assemblies honeywel l 1 micr o switc h sensin g an d contro l 1 1 -800-537-694 5 us a 1 f 1 - 8 1 5-235-684 7 internationa l 1 1 -800-737-336 0 canad a 131 6at series features 1 2-position, momentary and maintained action. 1 1, 2 o r 3 spdt precision basic switches. 1 short behind-panel depth. 1 choice of 1 4 or 15 32 -inch bushings. 1 silver or gold contacts. 1 ul recognized, csa certified basic switches. electrical ratings e basic switches 30 vdc rating amps ul/csa rating load sea level 50,000 ft. silver 5 amps, inductive 3 2.5 contacts 125-250 vac resistive 5 5 max. inrush 24 24 gold 1 amp, inductive 0.5 0.5 contacts 125 vac resistive 1 1 max. inrush 2 2 2-position order guide toggle lever position number mounting opposite of types solder `` t'' `` t2'' style keyway keyway poles contacts terminals terminals terminals 1 4 n bushing maint. maint. 1 silver 6at2 6at2-t 6at2-t2 with key tab 6at68-t* 6at68-t2* gold 6at23 6at23-t2 2 silver 6at3 6at3-t 6at3-t2 gold e 6at13-t 6at13-t2 3 silver 6at501 6at501-t 1 4 n bushing maint. maint. 1 silver 6at1 6at1-t 6at1-t2 without key tab gold 6AT56-T2 2 silver 6at4 e 6at4-t2 1 4 n bushing maint. maint. 1 silver 6at201-t with key washer 2 gold 6at231-t2 15 32 n bushing maint. maint. 1 silver 6at6 6at6-t 6at6-t2 with key washer gold 6at17 6at17-t2 2 silver 6at7 6at7-t gold 6at42 6at42-t2 3 silver 6at10 6at10-t 6at10-t2 gold 6at18 6at18-t2 * extra long toggle lever (.67 n /17,0 mm). toggle/rockers
manual switches at series toggle switch assemblies 1 3 2 honeywel l 1 micr o switc h sensin g an d contro l 1 1 -800-537-694 5 us a 1 f 1 - 8 1 5-235-684 7 internationa l 1 1 -800-737-336 0 canada 13at/23at series standard lever tab lever pull-to-unlock lever features 1 2 o r 3-position, momentary and maintained action. 1 2, 3 o r 4 spdt precision basic switches. 1 standard toggle, tab, or pull-to-unlock levers. 1 silver or gold contacts. 1 15 32 -inch bushing. 1 ul recognized, csa certified basic switches. 1 lever-to-bushing seal option. electrical ratings e basic switches 30 vdc rating amps ul/csa rating load sea level 50,000 ft. silver 5 amps, inductive 3 2.5 contacts 125-250 vac resistive 5 5 max. inrush 24 24 gold 1 amp, inductive 0.5 0.5 contacts 125 vac resistive 1 1 max. inrush 2 2 pull-to-unlock toggle levers as a guard against accidental operation, pull-to-unlock toggle levers must be pulled .090 inch/2, 3 m m (approx.) to change positions. a chart showing the 13 locking configurations and their catalog listing suffix code letters is shown on next page. 2-position order guides pull-to-unlock lever toggle lever position standard lever tab lever solder terminals opposite no. of type solder `` t'' `` t2'' `` t2'' (add locking letter 1 keyway keyway poles contacts terminals terminals terminals terminals to cat. listings below) maint. maint. 2 silver 23at1 23at1-t 23at1-t2 23at402-t2 23at1- locking letters: d, f, or g gold 23at11 23at11-t2 23at11- 3 silver 23at2 23at2-t 23at2-t2 23at2- gold 23at12 23at12-t2 23at12- 4 silver 23at3 23at3-t 23at3-t2 23at3- gold 23at8 mom. maint. 2 silver 23at4 23at4-t 23at4-t2 23at403-t2 gold 23at19 3 silver 23at5 gold 4 silver 23at6 23at6-t2 gold 1 see locking chart on next page. mil-s-8805/26 versions toggle lever position standard lever tab lever `` t2'' terminals `` t2'' terminals opposite no. of type keyway keyway poles contacts catalog listing military no. catalog listing military no. maint. maint. 2 silver 23at73-t2 m8805/26-001 23at473-t2 m8805/26-003 4 silver 23at74-t2 m8805/26-002 23at474-t2 m8805/26-004
manual switches at series toggle switch assemblies honeywel l 1 micr o switc h sensin g an d contro l 1 1 -800-537-694 5 us a 1 f 1 - 8 1 5-235-684 7 internationa l 1 1 -800-737-336 0 canad a 1 33 13at/23at series 3-position order guides pull-to-unlock lever toggle lever position standard lever tab lever solder terminals opposite no. of type solder `` t'' `` t2'' `` t2'' (add locking letter keyway center keyway poles contacts terminals terminals terminals terminals to cat. listings below) maint. maint. maint. 2 silver 13at2 13at2-t 13at2-t2 13at402-t2 13at2- locking letters: all types gold 13at18 13at18-t 3 silver 13at5 13at5- 4 silver 13at9 13at9-t2 13at409-t2 13at9- gold 13at29 mom. maint. mom. 2 silver 13at1 13at1-t 13at1-t2 13at401-t2 13at1- locking letters: e, l, or n gold 13at26 13at423-t2 3 silver 13at4 13at413-t2 4 silver 13at8 13at8-t2 13at8- gold maint. maint. mom. 2 silver 13at3 13at3-t 13at3-t2 13at403-t2 13at3- locking letters: e, g, b, l, p or n gold 4 silver 13at10 13at410-t2 13at10- mil-s-8805/26 versions toggle lever position standard lever tab lever `` t2'' terminals `` t2'' terminals opposite no. of type keyway center keyway poles contacts catalog listing military no. catalog listing military no. mom. maint. mom. 2 silver 13at271-t2 m8805/26-005 13at471-t2 m8805/26-006 3 silver 13at474-t2 m8805/26-012 maint. maint. maint. 2 silver 13at272-t2 m8805/26-007 13at472-t2 m8805/26-008 3 silver 13at275-t2 m8805/26-013 maint. maint. mom. 2 silver 13at273-t2 m8805/26-009 13at473-t2 m8805/26-010 lever-to-bushing seal option a splash type lever-to-bushing seal can be provided to help prevent the entrance of moisture and dust behind the panel, or into the contact area. to specify 2-posi- tion switches with lever-to-bushing seals, change the 23at catalog listing prefix to 32at. example: 32at1 is a sealed 23at1. convert 3-position catalog listings by changing the 13at prefix to 31at. exam- ple: 31at2-t is a sealed 13at2-t. hermetically sealed basic switch option at's with 15 32 n bushings can be furnished with hm or hs hermetically sealed basic switches, which have metal-to-metal fusion around the cover, actuator base and mounting holes. terminals are sealed glass-to-metal. the 1 4 n bushing 6at design can also be provided with hm basic switches. for more information, contact the 800 number. shown with hm basic switches locking configurations abdefgh locked in locked out of center and locked out locked in locked in center and locked in extreme position of center locked in extreme position extreme position extreme position three positions (keyway side) position center position (opposite keyway) (keyway side) (keyway side) jklmnp locked out of locked in locked out of locked out of center and center and locked out of and into locked out of and into extreme position extreme position extreme position extreme position extreme position extreme position (opposite keyway) (opposite keyway) (keyway side) (opposite keyway) (opposite keyway) (keyway side) toggle/rockers
manual switches at series toggle switch assemblies 1 3 4 honeywel l 1 micr o switc h sensin g an d contro l 1 1 -800-537-694 5 us a 1 f 1 - 8 1 5-235-684 7 internationa l 1 1 -800-737-336 0 canada mounting dimensions (for reference only) 13/23at 6at panel cutouts 1 4 n bushing 15 32 n bushing notee 64at300, 66at300, and 68at300 (m8805/98) listings have a bushing seal and ms25196 panel seal. bushing mounting torque is 1015 in./lbs.


▲Up To Search▲   

 
Price & Availability of 6AT56-T2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X